| MRC |
Requirement Statement |
Reply Statement |
| AAPE |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS |
-50.0 TO 50.0 LOCATION NOT OTHERWISE SPECIFIED |
| AAPP |
ELECTRICAL RESISTANCE |
10.000 KILOHMS LOWEST RESISTANCE VALUE |
| AAPP |
ELECTRICAL RESISTANCE |
80.000 KILOHMS HIGHEST RESISTANCE VALUE |
| AAPP |
ELECTRICAL RESISTANCE |
20.000 KILOHMS FIRST INTERMEDIATE RESISTANCE VALUE |
| AAPP |
ELECTRICAL RESISTANCE |
40.000 KILOHMS SECOND INTERMEDIATE RESISTANCE VALUE |
| AAPQ |
RESISTANCE TOLERANCE IN PERCENT |
-10.000 TO 10.000 EACH RESISTOR |
| AAQF |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER |
25.0 |
| AAQG |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER |
125.0 |
| AAQH |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS |
-55.0 TO 125.0 LOCATION NOT OTHERWISE SPECIFIED |
| AAQZ |
INCLOSURE METHOD |
ENCAPSULATED |
| AARA |
TERMINAL QUANTITY |
14 |
| AARB |
TERMINAL TYPE |
PIN |
| ABJT |
TERMINAL LENGTH |
0.250 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
0.265 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
0.375 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
0.055 INCHES NOMINAL |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
4 BALANCED LADDER NETWORK |
| AEFB |
POWER DISSIPATION RATING IN WATTS |
0.060 EACH RESISTOR LOCATION NOT OTHERWISE SPECIFIED |
| CQRD |
IDENTICAL VALUE RESISTOR QUANTITY |
1 LOWEST RESISTANCE VALUE |
| CQRD |
IDENTICAL VALUE RESISTOR QUANTITY |
2 HIGHEST RESISTANCE VALUE |
| CQRD |
IDENTICAL VALUE RESISTOR QUANTITY |
1 FIRST INTERMEDIATE RESISTANCE VALUE |
| CQRD |
IDENTICAL VALUE RESISTOR QUANTITY |
1 SECOND INTERMEDIATE RESISTANCE VALUE |
| STYL |
STYLE DESIGNATOR |
219 FLAT PACK |