| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABJT |
TERMINAL LENGTH |
1.380 INCHES MINIMUM |
| ADAQ |
BODY LENGTH |
0.328 INCHES NOMINAL |
| ADAR |
BODY OUTSIDE DIAMETER |
0.140 INCHES NOMINAL |
| AEBT |
TERMINAL DIAMETER |
0.032 INCHES NOMINAL |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 CELSIUS |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 CELSIUS |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
25.0 |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
11.0 |
| AEJC |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS |
-4.96 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-20.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
40.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
60.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
80.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
120.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
140.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
240.0 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
75.9 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
28.4 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
13.0 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
6.0 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.0 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.8 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.0 KILOHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
750.0 OHMS NINTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
400.0 OHMS TENTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-19.2 TO 19.2 FIRST RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-17.8 TO 17.8 SECOND RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.1 TO 15.1 THIRD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.3 TO 10.3 FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-12.6 TO 12.6 FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-13.9 TO 13.9 SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.6 TO 15.6 SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-17.2 TO 17.2 EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-19.1 TO 19.1 NINTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-20.8 TO 20.8 TENTH RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| CBME |
CUBIC MEASURE |
0.004 CUBIC INCHES |
| CQWD |
ZERO POWER RESISTANCE |
10.000 KILOHMS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0 TO 10.0 |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| SFTT |
SURFACE TREATMENT |
SOLDER TERMINAL |
| STYL |
STYLE DESIGNATOR |
16 ROD |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |