| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABDN |
TERMINAL SURFACE TREATMENT |
SOLDER |
| ABJT |
TERMINAL LENGTH |
1.250 INCHES NOMINAL |
| ADAR |
BODY OUTSIDE DIAMETER |
0.100 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
0.070 INCHES NOMINAL |
| AEBT |
TERMINAL DIAMETER |
0.013 INCHES NOMINAL |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 CELSIUS |
| AEHZ |
MAXIMUM OPERATING TEMP |
150.0 CELSIUS |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
10.0 |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
4.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-40.0 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-21.5 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
37.8 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
104.4 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 CELSIUS |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 CELSIUS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
95.0 KILOHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
34.0 KILOHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
10.5 KILOHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.3 KILOHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
560.0 OHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
360.0 OHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
150.0 OHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
59.5 OHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
33.5 OHMS |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
18.0 OHMS |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-18.9 TO 18.9 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.6 TO 16.6 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-14.2 TO 14.2 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-12.6 TO 12.6 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-13.7 TO 13.7 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.1 TO 15.1 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-16.9 TO 16.9 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-17.8 TO 17.8 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-18.9 TO 18.9 |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-20.1 TO 20.1 |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| CBME |
CUBIC MEASURE |
0.0004 CUBIC INCHES |
| CQWD |
ZERO POWER RESISTANCE |
1.000 KILOHMS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0 TO 10.0 |
| CTGT |
REFERENCE TEMP IN DEG CELSIUS |
25.0 |
| PKWT |
UNPACKAGED UNIT WEIGHT |
0.891 GRAMS |
| STYL |
STYLE DESIGNATOR |
20 ROUND BODY, PIN TERMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |