| MRC |
Requirement Statement |
Reply Statement |
| AAPN |
SECTION QUANTITY |
11 |
| AAQL |
BODY STYLE |
5B CYLINDRICAL SERVO MOUNTED |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AAVL |
PILOT DIAMETER |
0.9688 INCHES NOMINAL |
| AAVM |
PILOT LENGTH |
0.6200 INCHES NOMINAL |
| ABNB |
FIRST FLAT LENGTH |
0.375 INCHES NOMINAL |
| ABNC |
FLAT HEIGHT |
0.105 INCHES NOMINAL |
| ABPA |
UNDERCUT DIAMETER |
0.968 INCHES NOMINAL |
| ABPC |
UNDERCUT WIDTH |
0.0570 INCHES MINIMUM |
| ABPM |
BODY DIAMETER |
1.062 INCHES NOMINAL |
| ABWV |
SHAFT DIAMETER |
0.1247 INCHES NOMINAL |
| ABXF |
SHAFT LENGTH |
0.437 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
2.680 INCHES NOMINAL |
| AECZ |
MOUNTING LIP DIAMETER |
1.0750 INCHES MAXIMUM |
| AEDA |
MOUNTING LIP DEPTH |
0.0620 INCHES NOMINAL |
| AEDX |
SHAFT STYLE |
2C ROUND, FLATTED |
| AEFD |
ACTUATOR TYPE |
SINGLE SHAFT |
| AEFH |
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION |
340.0 NOMINAL |
| AEFK |
MAXIMUM STARTING TORQUE |
3.45 INCH-OUNCES |
| AEFL |
MAXIMUM RUNNING TORQUE |
3.45 INCH-OUNCES |
| AEFM |
MAXIMUM STOP TORQUE |
32.00 INCH-OUNCES |
| AEFY |
SHAFT END PLAY |
0.005 INCHES |
| AEFZ |
SHAFT RUNOUT |
0.002 INCHES |
| AEGA |
LATERAL RUNOUT |
0.001 INCHES |
| AEGB |
PILOT DIAMETER RUNOUT |
0.001 INCHES |
| AEGC |
SHAFT RADIAL PLAY |
0.001 INCHES |
| AXGY |
MOUNTING METHOD |
CLAMP RING(S) |
| BYDT |
BEARING TYPE |
BALL SHAFT |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
10.0 KILOHMS 1ST SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
7.5 KILOHMS 2ND SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
30.0 KILOHMS 3RD SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
7.5 KILOHMS 4TH SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
20.0 KILOHMS 5TH SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
20.0 KILOHMS 6TH SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
20.0 KILOHMS 7TH SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
20.0 KILOHMS 8TH SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
2.0 KILOHMS 9TH SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
30.0 KILOHMS 10TH SECTION |
| CQCC |
ELECTRICAL RESISTANCE PER SECTION |
30.0 KILOHMS 11TH SECTION |
| CQCH |
TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION |
38.17 2ND SECTION AND 87.27 2ND SECTION AND 136.37 2ND SECTION |
| CQCH |
TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION |
38.17 4TH SECTION AND 87.27 4TH SECTION AND 136.37 4TH SECTION |
| CQCH |
TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION |
156.36 5TH SECTION |
| CQCH |
TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION |
156.36 6TH SECTION AND 232.72 6TH SECTION |
| CQCH |
TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION |
156.36 7TH SECTION |
| CQCH |
TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION |
156.36 8TH SECTION AND 232.72 8TH SECTION |
| CQCK |
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG |
360.0 NOMINAL |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-0.25 TO 0.25 1ST SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-1.00 TO 1.00 2ND SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-0.65 TO 0.65 3RD SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-1.00 TO 1.00 4TH SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-1.50 TO 1.50 5TH SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-1.50 TO 1.50 6TH SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-1.50 TO 1.50 7TH SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-1.50 TO 1.50 8TH SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-2.00 TO 2.00 9TH SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-0.65 TO 0.65 10TH SECTION |
| CQFL |
FUNCTION CONFORMITY TOLERANCE PER SECTION |
-0.30 TO 0.30 11TH SECTION |
| CQGN |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER |
100.0 ALL SECTIONS |
| CQTM |
TERMINAL LOCATION |
RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE LOCATION NOT OTHERWISE SPECIFIED |
| CRFJ |
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS |
-400.0 TO 400.0 ALL SECTIONS |
| CRGD |
POWER DISSIPATION RATING PER SECTION IN WATTS |
1.0 FREE AIR ALL SECTIONS |
| CRGM |
FUNCTION CONFORMITY PER SECTION |
ALL SECTIONS ABSOLUTE CONFORMITY |
| CRJS |
FIXED TAP QUANTITY PER SECTION |
3 2ND SECTION |
| CRJS |
FIXED TAP QUANTITY PER SECTION |
3 4TH SECTION |
| CRJS |
FIXED TAP QUANTITY PER SECTION |
1 5TH SECTION |
| CRJS |
FIXED TAP QUANTITY PER SECTION |
2 6TH SECTION |
| CRJS |
FIXED TAP QUANTITY PER SECTION |
1 7TH SECTION |
| CRJS |
FIXED TAP QUANTITY PER SECTION |
2 8TH SECTION |
| CRKS |
TAP LOCATION TOLERANCE PER SECTION |
-2.0 TO 2.0 DEG ANGULAR ROTATION ALL SECTIONS |
| CRSS |
RESISTANCE TOLERANCE PER SECTION IN PERCENT |
-10.0 TO 10.0 ALL SECTIONS |
| CRSX |
ACTUATOR TRAVEL CONTROL FEATURE |
CONTINUOUS MOTION |
| CSBX |
FUNCTION CHARACTERISTIC PER SECTION |
ALL SECTIONS EQUATION |
| CSDH |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER |
25.0 ALL SECTIONS |
| TEST |
TEST DATA DOCUMENT |
97942-577R900 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TTQY |
TERMINAL TYPE AND QUANTITY |
45 TURRET |