| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABJT |
TERMINAL LENGTH |
1.250 INCHES MINIMUM |
| ADAQ |
BODY LENGTH |
0.410 INCHES NOMINAL |
| ADAR |
BODY OUTSIDE DIAMETER |
0.140 INCHES NOMINAL |
| AEBT |
TERMINAL DIAMETER |
0.025 INCHES NOMINAL |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
500.00 MILLIWATTS |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 CELSIUS |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 CELSIUS |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
60.0 |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
5.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-15.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
1.7 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
2.4 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
4.1 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
4.8 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
5.5 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
6.5 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-20.0 TO 20.0 FIRST RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-14.0 TO 14.0 SECOND RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-12.0 TO 12.0 THIRD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-14.0 TO 14.0 FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-17.0 TO 17.0 FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-20.0 TO 20.0 SIXTH RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| CQWD |
ZERO POWER RESISTANCE |
3.300 KILOHMS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0 TO 10.0 |
| STYL |
STYLE DESIGNATOR |
15 ROD |
| TEST |
TEST DATA DOCUMENT |
81349-MILT23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |