| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABJT |
TERMINAL LENGTH |
0.188 INCHES MINIMUM |
| ADAQ |
BODY LENGTH |
0.100 INCHES MAXIMUM |
| ADAR |
BODY OUTSIDE DIAMETER |
0.041 INCHES NOMINAL |
| AEBT |
TERMINAL DIAMETER |
0.004 INCHES NOMINAL |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 CELSIUS |
| AEHZ |
MAXIMUM OPERATING TEMP |
300.0 CELSIUS |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
8.0 |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
0.35 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
150.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
300.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
274.4 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
29.6 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
3.9 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
833.5 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
249.1 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
22.6 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-15.0 TO 15.0 FIRST RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-7.0 TO 7.0 SECOND RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-7.0 TO 7.0 THIRD RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-17.0 TO 17.0 FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-27.0 TO 27.0 FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-57.0 TO 57.0 SIXTH RESISTANCE-TEMPERATURE POINT |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| CQWD |
ZERO POWER RESISTANCE |
10.000 KILOHMS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-2.0 TO 2.0 |
| STYL |
STYLE DESIGNATOR |
4 SEALED OR COATED BEAD |
| TEST |
TEST DATA DOCUMENT |
82577-954026 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |