National Stock Number(NSN): 5820-00-082-4080 (5820000824080, 000824080)
| NIIN: |
00-082-4080 |
Item Name: |
RECEIVER-TRANSMITTER,RADIO |
INC: |
19506
|
| FSC: |
5820
|
Assignment Date: |
Jan-01-1961 |
CRIT: |
X |
IIG: |
19506 |
| ISC: |
1 |
Date Standardized: |
Nov-27-2000 |
HMIC: |
P |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
A |
FIIG: |
T199-D |
| ESD: |
|
Schedule B: |
8529.90.6000 |
DEMIL: |
D |
DEMIL INT: |
1 |
| TIIC: |
1 |
Originator: |
TX |
ADPEC: |
0 |
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
522-1792-00 |
13499
|
ROCKWELL COLLINS, INC. |
C |
3 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
522-1792-000 |
13499
|
ROCKWELL COLLINS, INC. |
C |
3 |
2 |
5 |
CL |
3 |
D |
|
|
|
|
|
RT718FRC93 |
80058
|
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM |
C |
5 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
522-1792-000 |
95105
|
ROCKWELL COLLINS, INC. |
H |
3 |
2 |
|
|
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
|
|
|
|
|
|
A |
$0.00 |
|
|
------- |
Jul-01-2005 |
H |
| DF |
FLZ |
V |
S |
0 |
7 |
1 |
L |
$1,649.00 |
EA |
|
--LSJ-N |
Dec-01-2019 |
C |
| DM |
MPB |
Y |
|
0 |
Y |
1 |
M |
$1,649.00 |
EA |
|
3143-22 |
Dec-01-2020 |
H |
| DN |
N35 |
J |
H |
0 |
Y |
1 |
N |
$1,650.00 |
EA |
|
7G--00- |
Oct-01-1994 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DF |
7 |
SUBSTITUTE FOR 5820-00-566-8373 |
000 |
|
AAA |
|
| DF |
|
I & S MASTER |
000 |
|
ABA |
|
| DM |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
14.750 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
7.750 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
14.000 INCHES NOMINAL |
| ACYR |
DC VOLTAGE RATING |
830.0 VOLTS NOMINAL FIRST OPERATING POWER RQMT |
| ACYR |
DC VOLTAGE RATING |
275.0 VOLTS NOMINAL SECOND OPERATING POWER RQMT |
| ACYR |
DC VOLTAGE RATING |
-60.0 VOLTS MINIMUM THIRD OPERATING POWER RQMT |
| ACYR |
DC VOLTAGE RATING |
-80.0 VOLTS MAXIMUM FOURTH OPERATING POWER RQMT |
| ACYR |
DC VOLTAGE RATING |
24.0 VOLTS NOMINAL FIFTH OPERATING POWER RQMT |
| ACYR |
DC VOLTAGE RATING |
12.0 VOLTS NOMINAL SIXTH OPERATING POWER RQMT |
| ACYR |
DC VOLTAGE RATING |
6.0 VOLTS NOMINAL SEVENTH OPERATING POWER RQMT |
| AKWA |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME |
RECEIVER-TRANSMITTER |
| AKWB |
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER |
TYPE NO. RT-718/FRC-93 |
| AMKE |
TRANSMITTER BAND QUANTITY |
12 |
| AMKM |
TRANSMITTER CHANNEL QUANTITY |
2 |
| AMKP |
RECEIVER BAND QUANTITY |
12 |
| AMKQ |
RECEIVER CHANNEL QUANTITY |
2 |
| AMMS |
POWER OUTPUT |
100.000 WATTS MAXIMUM |
| APTQ |
INPUT FREQUENCY RATING |
3.400 MEGAHERTZ MINIMUM AND 30.000 MEGAHERTZ MAXIMUM |
| APTS |
OUTPUT FREQUENCY RATING |
3.400 MEGAHERTZ MINIMUM AND 30.000 MEGAHERTZ MAXIMUM |
| BCXN |
TRANSMITTER EMISSION TYPE |
A3A |
| BCXP |
RECEIVER EMISSION TYPE |
A3A |
| ZZZV |
FSC APPLICATION DATA |
RECEIVER-TRANSMITTER,RADIO,EXCEPT NAVIGATION,NONAIRBORNE |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| FGG4 |
FAA4 |
Dec-01-1999 |
3 |
H |
D |
|
TU |
TU |
| ZH01 |
|
Apr-01-1991 |
|
|
|
|
ZH |
ZH |
| ZK01 |
|
Nov-01-1993 |
|
|
|
|
ZK |
ZK |
| ZU01 |
|
Apr-01-1991 |
|
|
|
|
ZU |
ZU |
| ZW01 |
|
Nov-01-2005 |
|
|
|
|
ZW |
ZW |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| FSC |
NIIN |
ISC |
Originator |
NSC |
Std. Date |
Status |
|
5820
|
00-566-8373
|
3 |
TX |
0 |
Nov-27-2000 |
C |
| Obsolete NIIN Information |
| Description: |
RADIO/TV TRANSMIT/RECEIVE SETS SUB1 |
Originating Activity: |
XX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
062820 |
| Less Than One Truckload: |
J |
NMFC Sub-Item: |
A |
| Uniform Freight Classification Number: |
35080 |
Rail Variance Code: |
1 |
| Less Than One Carload: |
|
Water Commodity Code: |
72D |
| Type of Cargo Code: |
Z |
Special Handling Code: |
Z |
| Air Commodity Special Handling Code: |
HZ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
ZZZ0 |
| Lvl A Pkg Req: |
0 |
Unit Pack Size: |
22.8x19.8x15.0 |
Pres Material: |
00 |
| Lvl B Pkg Req: |
F |
Unit Pack Weight: |
28.5 |
Pres Method: |
DW |
| Lvl C Pkg Req: |
0 |
Unit Pack Cube: |
3.918 |
Wrapping Mat: |
ZZ |
| Opt Proc Ind: |
A |
Unpkg Item Dims: |
16.0x14.0x8.0 |
Spec Marking: |
ZZ |
| Container FSC: |
|
SPI Number: |
F000344227 |
SPI Revision: |
B |
| Unpkg Weight: |
18.0 |
SPI Date: |
Oct-31-2018 |
Pkg Design Activity: |
|
| Inter Container Qty: |
000 |
Inter Container Code: |
00 |
Clean/Dry Procedure: |
1 |
| Unit Container: |
ED |
Item Type Storage: |
|
Unit Container Level: |
B |
| |
|
Cush/Dun Material: |
ZZ |
Cush/Dun Thickness: |
Z |
| Source: |
A |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats |
Status: |
H |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
|
| Lvl A Pkg Req: |
0 |
Unit Pack Size: |
|
Pres Material: |
00 |
| Lvl B Pkg Req: |
F |
Unit Pack Weight: |
2850.0 |
Pres Method: |
DW |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
391.000 |
Wrapping Mat: |
ZZ |
| Opt Proc Ind: |
A |
Unpkg Item Dims: |
|
Spec Marking: |
ZZ |
| Container FSC: |
|
SPI Number: |
F000344227 |
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
|
Pkg Design Activity: |
|
| Inter Container Qty: |
|
Inter Container Code: |
00 |
Clean/Dry Procedure: |
1 |
| Unit Container: |
ED |
Item Type Storage: |
|
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
ZZ |
Cush/Dun Thickness: |
Z |
|