| MRC |
Requirement Statement |
Reply Statement |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
A1 ROUND |
| AARX |
INSIDE DIAMETER |
1.000 INCHES NOMINAL |
| ABJH |
TEMP RATING |
-40.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |
| ABKU |
FLANGE THICKNESS |
0.375 INCHES NOMINAL FIRST END |
| ABKU |
FLANGE THICKNESS |
0.405 INCHES NOMINAL SECOND END |
| ABKV |
OUTSIDE DIAMETER |
1.520 INCHES NOMINAL |
| ACKH |
MINIMUM INSIDE BENDING RADIUS |
12.000 INCHES |
| ADKX |
ANGLE BETWEEN RIGID ELBOW FITTINGS IN DEG |
160.0 |
| ADUY |
CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH |
1.094 INCHES NOMINAL FIRST END |
| ADUY |
CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH |
1.350 INCHES NOMINAL SECOND END |
| ADUZ |
CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH |
2.250 INCHES NOMINAL FIRST END |
| ADUZ |
CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH |
2.250 INCHES NOMINAL SECOND END |
| AECS |
BOLT HOLE QUANTITY |
4 FIRST END |
| AECS |
BOLT HOLE QUANTITY |
4 SECOND END |
| AFQN |
FLANGE LENGTH |
3.160 INCHES MINIMUM AND 3.220 INCHES MAXIMUM FIRST END |
| AFQN |
FLANGE LENGTH |
3.720 INCHES MINIMUM AND 3.780 INCHES MAXIMUM SECOND END |
| AGAV |
END ITEM IDENTIFICATION |
2350-01-390-4683 |
| AGFF |
FLANGE WIDTH |
2.660 INCHES NOMINAL FIRST END |
| AGFF |
FLANGE WIDTH |
1.480 INCHES NOMINAL SECOND END |
| AHNC |
CONNECTION STYLE |
G12 PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) FIRST END |
| AHNC |
CONNECTION STYLE |
G12 PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) SECOND END |
| AHNX |
BOLT HOLE DIAMETER |
0.469 INCHES NOMINAL FIRST END |
| AHNX |
BOLT HOLE DIAMETER |
0.406 INCHES NOMINAL SECOND END |
| AKUT |
END FLANGE CONSTRUCTION |
SOLID FIRST END |
| AKUT |
END FLANGE CONSTRUCTION |
SOLID SECOND END |
| AKUU |
END CONNECTION DESIGN |
ELBOW FIRST END |
| AKUU |
END CONNECTION DESIGN |
ELBOW SECOND END |
| AWLS |
CONNECTION TYPE |
PLAIN FACE FLANGE FIRST END |
| AWLS |
CONNECTION TYPE |
PLAIN FACE FLANGE SECOND END |
| CQBD |
BURST TEST PRESSURE |
20000.0 POUNDS PER SQUARE INCH |
| CQQF |
OPERATING PRESSURE |
5000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| CRDW |
HYDROSTATIC TEST PRESSURE |
10000.0 POUNDS PER SQUARE INCH |
| CRFY |
FLOW ANGLE |
45.0 DEGREES FIRST END |
| CRFY |
FLOW ANGLE |
45.0 DEGREES SECOND END |
| CRWL |
INSIDE SURFACE CONDITION |
SMOOTH |
| CRXX |
MEASURING METHOD AND LENGTH |
21.750 INCHES NOMINAL OVERALL |
| CTCJ |
FLANGE STYLE |
K1 DOUBLE OVAL (SAE SPLIT TYPE FLANGE) FIRST END |
| CTCJ |
FLANGE STYLE |
K1 DOUBLE OVAL (SAE SPLIT TYPE FLANGE) SECOND END |
| MEDA |
MEDIA FOR WHICH DESIGNED |
FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
WRAPPED RUBBER, SYNTHETIC OUTER LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE FIRST LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE SECOND LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE THIRD LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE FOURTH LAYER |