National Stock Number(NSN): 4520-01-042-0099 (4520010420099, 010420099)
| NIIN: |
01-042-0099 |
Item Name: |
HEATER,DUCT TYPE,STATIONARY |
INC: |
17014
|
| FSC: |
4520
|
Assignment Date: |
Jun-06-1977 |
CRIT: |
N |
IIG: |
17014 |
| ISC: |
2 |
Date Standardized: |
Nov-20-1984 |
HMIC: |
N |
DODIC: |
|
| NSC: |
4 |
Cancellation Date: |
Oct-12-2004 |
PMIC: |
U |
FIIG: |
A01300 |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
1 |
Originator: |
AX |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
DF0406 |
58823
|
WELLMAN THERMAL SYSTEMS CORP |
H |
3 |
2 |
5 |
AX |
1 |
A |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DS |
S9I |
J |
|
0 |
U |
1 |
D |
$567.61 |
EA |
|
------- |
Oct-01-2003 |
H |
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AAXX |
MOUNTING TYPE |
VENTILATION DUCT |
| ABAM |
HEAT MEDIUM TYPE |
AIR |
| ABGL |
WIDTH |
6.000 INCHES NOMINAL |
| ACDC |
CURRENT TYPE |
AC |
| AEJZ |
DEPTH |
6.000 INCHES NOMINAL |
| ALYC |
OPERATING CONTROL TYPE |
THERMAL SWITCH |
| AMPS |
CURRENT RATING IN AMPS |
18.0 |
| BDXJ |
HEATING ELEMENT TYPE |
ELECTRIC NONIMMERSION |
| CQSJ |
INCLOSURE MATERIAL |
STEEL CORROSION RESISTING |
| CQXD |
HEAT DELIVERY RATE |
12795.0 BRITISH THERMAL UNIT |
| ELEC |
VOLTAGE IN VOLTS |
208.0 |
| FAAZ |
PHASE |
THREE |
| FREQ |
FREQUENCY IN HERTZ |
50.0 |
| HGTH |
HEIGHT |
8.000 INCHES NOMINAL |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| DKZ1 |
DAX1 |
Jan-01-1997 |
3 |
H |
|
|
|
AX |
|