National Stock Number(NSN): 4140-00-950-6167 (4140009506167, 009506167)
| NIIN: |
00-950-6167⛔ |
Item Name: |
FAN,VANEAXIAL |
INC: |
04245
|
| FSC: |
4140
|
Assignment Date: |
Jan-01-1962 |
CRIT: |
N |
IIG: |
04245 |
| ISC: |
3 |
Date Standardized: |
Nov-30-1984 |
HMIC: |
N |
DODIC: |
|
| NSC: |
5 |
Cancellation Date: |
Nov-01-2001 |
PMIC: |
U |
FIIG: |
A087A0 |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
K |
Originator: |
CX |
ADPEC: |
|
RPDMRC: |
|
| NIIN: |
00-018-6781 |
Item Name: |
FAN,VANEAXIAL |
| FSC: |
4140 |
Replacement Date: |
Nov-01-2001 |
|
INC: |
04245 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
020630 |
82877
|
ROTRON INCORPORATED |
H |
3 |
2 |
6 |
CX |
|
|
|
|
|
|
|
104-001-0003 |
95542
|
NORTHROP GRUMMAN SYSTEMS CORPORATION |
H |
5 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
A0-30486 |
82877
|
ROTRON INCORPORATED |
H |
5 |
2 |
A |
CX |
|
|
|
|
|
|
|
AXIMAX2H-395JH |
82877
|
ROTRON INCORPORATED |
H |
5 |
1 |
E |
CX |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DN |
S9I |
V |
|
0 |
U |
1 |
N |
$53.07 |
EA |
|
9Z----- |
Feb-01-1997 |
H |
| DS |
S9I |
Y |
|
0 |
U |
1 |
D |
$53.07 |
EA |
|
------- |
Sep-01-2001 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DN |
F |
WHN EXHST USE 4140-00-018-6781 |
000 |
|
|
|
| DS |
F |
WHN EXHST USE 4140-00-018-6781 |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABBB |
SPEED ADJUSTMENTS |
SINGLE SPEED |
| ABRY |
LENGTH |
1.406 INCHES NOMINAL |
| ADNK |
FLOW DIRECTION |
OUTWARD |
| ADZC |
ENVIRONMENTAL PROTECTION |
WEATHERPROOF |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
125.0 CELSIUS |
| AEQC |
OPERATING SPEED AT RATED CAPACITY IN RPM |
11000.0 |
| AGBD |
ELECTRICAL CONNECTION TYPE |
TERMINAL BLOCK |
| AJLY |
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE |
0.0 INCHES OF WATER |
| AKCV |
DRIVE TYPE |
DIRECT |
| AKDJ |
PRIME MOVER TYPE |
ELECTRIC MOTOR |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 RIM |
| AYSY |
ROTATION DIRECTION FOR WHICH DESIGNED |
COUNTERCLOCKWISE |
| CQKX |
AIR FLOW RATE |
32.0 CUBIC FEET PER MINUTE NOMINAL |
| CSBH |
VOLTAGE IN VOLTS AND CURRENT TYPE |
200.0 AC |
| CSYL |
PRIME MOVER POWER RATING |
24.0 WATTS |
| CWLX |
HOUSING INSIDE DIAMETER |
1.890 INCHES NOMINAL |
| CWLY |
PRIME MOVER DRIVE SHAFT BEARING TYPE |
BALL |
| FAAZ |
PHASE |
THREE |
| FREQ |
FREQUENCY IN HERTZ |
400.0 |
| MATT |
MATERIAL |
ALUMINUM ALLOY OVERALL |
| SFTT |
SURFACE TREATMENT |
ENAMEL OVERALL |
| STYL |
STYLE DESIGNATOR |
30 FIXED |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| N9ZD |
N9GD |
Nov-01-1996 |
3 |
H |
Z |
GH |
KE |
|
| TAN1 |
|
Dec-02-1996 |
|
|
|
|
|
|
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| FSC |
NIIN |
ISC |
Originator |
NSC |
Std. Date |
Status |
|
4140
|
00-018-6781
|
1 |
CX |
0 |
Oct-14-1984 |
H |
|